Search results

1 – 3 of 3
Article
Publication date: 7 February 2022

Tao Song, Bo Pan, Guojun Niu and Yili Fu

This study aims to represent a novel closed-form solutions method based on the product of the exponential model to solve the inverse kinematics of a robotic manipulator. In…

109

Abstract

Purpose

This study aims to represent a novel closed-form solutions method based on the product of the exponential model to solve the inverse kinematics of a robotic manipulator. In addition, this method is applied to master–slave control of the minimally invasive surgical (MIS) robot.

Design/methodology/approach

For MIS robotic inverse kinematics, the closed-form solutions based on the product of the exponential model of manipulators are divided into the RRR and RRT subproblems. Geometric and algebraic constraints are used as preconditions to solve two subproblems. In addition, several important coordinate systems are established on the surgical robot and master–slave mapping strategies are illustrated in detail. Finally, the MIS robot can realize master–slave control by combining closed-form solutions and master–slave mapping strategy.

Findings

The simulation of the instrument manipulator based on the RRR and RRT subproblems is executed to verify the correctness of the proposed closed-form solutions. The fact that the accuracy of the closed-form solutions is better than that of the compensation method is validated by the contrastive linear trajectory experiment, and the average and the maximum tracking errors are 0.1388 mm and 0.3047 mm, respectively. In the animal experiment, the average and maximum tracking error of the left instrument manipulator are 0.2192 mm and 0.4987 mm, whereas the average and maximum tracking error of the right instrument manipulator are 0.1885 mm and 0.6933 mm. The successful completion of the animal experiment comprehensively demonstrated the feasibility and reliability of the master–slave control strategy based on the novel closed-form solutions.

Originality/value

The proposed closed-form solutions are error-free in theory. The master–slave control strategy is not affected by calculation error when the closed-form solutions are used in the surgical robot. And the accuracy and reliability of the master–slave control strategy are greatly improved.

Details

Industrial Robot: the international journal of robotics research and application, vol. 49 no. 5
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 20 June 2008

U. Hagn, M. Nickl, S. Jörg, G. Passig, T. Bahls, A. Nothhelfer, F. Hacker, L. Le‐Tien, A. Albu‐Schäffer, R. Konietschke, M. Grebenstein, R. Warpup, R. Haslinger, M. Frommberger and G. Hirzinger

Surgical robotics can be divided into two groups: specialized and versatile systems. Versatile systems can be used in different surgical applications, control architectures and…

4903

Abstract

Purpose

Surgical robotics can be divided into two groups: specialized and versatile systems. Versatile systems can be used in different surgical applications, control architectures and operating room set‐ups, but often still based on the adaptation of industrial robots. Space consumption, safety and adequacy of industrial robots in the unstructured and crowded environment of an operating room and in close human robot interaction are at least questionable. The purpose of this paper is to describe the DLR MIRO, a new versatile lightweight robot for surgical applications.

Design/methodology/approach

The design approach of the DLR MIRO robot focuses on compact, slim and lightweight design to assist the surgeon directly at the operating table without interference. Significantly reduced accelerated masses (total weight 10 kg) enhance the safety of the system during close interaction with patient and user. Additionally, MIRO integrates torque‐sensing capabilities to enable close interaction with human beings in unstructured environments.

Findings

A payload of 30 N, optimized kinematics and workspace for surgery enable a broad range of possible applications. Offering position, torque and impedance control on Cartesian and joint level, the robot can be integrated easily into telepresence (e.g. endoscopic surgery), autonomous or soft robotics applications, with one or multiple arms.

Originality/value

This paper considers lightweight and compact design as important design issues in robotic assistance systems for surgery.

Details

Industrial Robot: An International Journal, vol. 35 no. 4
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 21 August 2017

Weibang Bai, Qixin Cao, Pengfei Wang, Peng Chen, Chuntao Leng and Tiewen Pan

Robotic systems for laparoscopic minimally invasive surgery (MIS) always end up with highly sophisticated mechanisms and control schemes – making it a long and hard development…

Abstract

Purpose

Robotic systems for laparoscopic minimally invasive surgery (MIS) always end up with highly sophisticated mechanisms and control schemes – making it a long and hard development process with a steep price. This paper aims to propose and realize a new, efficient and convenient strategy for building effective control systems for surgical and even other complex robotic systems.

Design/methodology/approach

A novel method that takes advantage of the modularization concept by integrating two middleware technologies (robot operating system and robotic technology middleware) into a common architecture based on the strengths of both was designed and developed.

Findings

Tests of the developed control system showed very low time-delay between the master and slave sides; good movement representation on the slave manipulator; and high positional and operational accuracy. Moreover, the new development strategy trial came with much higher efficiency and lower costs.

Research limitations/implications

This method results in a modularized and distributed control system that is amenable to collaboratively develop; convenient to modify and update; componentized and easy to extend; mutually independent among subsystems; and practicable to be running and communicating across multiple operating systems. However, experiments show that surgical training and updates of the robotic system are still required to achieve better proficiency for completing complex minimally invasive surgical operations with the proposed and developed system.

Originality/value

This research proposed and developed a novel modularization design method and a novel architecture for building a distributed teleoperation control system for laparoscopic MIS.

Details

Industrial Robot: An International Journal, vol. 44 no. 5
Type: Research Article
ISSN: 0143-991X

Keywords

1 – 3 of 3